Power supply : AC220V±10%;50±1 Hz
Continuous working time with rechargeable cell : 30 hours
Working environment temperature : 10~50(℃)
Measuring range : 0.2~100(Ω·m)
Measuring uncertainty : 2.0~5.0(Ω·m)variable range in ±3% Others in ±5%
Measuring temperature range : 10~50(℃)with precision range in ±1℃
Setting of standard temperature : 15~35(℃) with step is 1℃
Compensation of auto-temperature : -10~10(℃)with step is 0.1℃
1.Summary
The Model DZL2003 resistivity measuring meter of drilling fluids is the newly developed instrument. It is mainly used to measure resistivity or conductivity of various fluids. It can also be applied to measure resisitivity of oil field drilling fluids and various liquids in other industries, and analyze liquid mineralization or provide reference for distinguishing water purity. The instrument is ideal liquid resistivity measuring apparatus and can be widely used to such departments as petroleum, geology, drilling team and laboratory.
Function
1) measuring liquid resistivity
2) measuring liquid temperature
3) automatic exchange of resistivity in standard temperature
4) setting of standard temperature
5) auto-compensation of temperature
6) self-check of measuring apparatus
7) with rechargeable cell set
2. Model DZL2003
3. The main technical parameters of apparatus
Sequence number | Name | Technical Parameters |
1 | Power supply | AC220V±10%;50±1 Hz |
2 | Continuous working time with rechargeable cell | 30 hours |
3 | Working environment temperature | 10~50(℃) |
4 | Measuring range | 0.2~100(Ω·m) |
5 | Measuring uncertainty | 2.0~5.0(Ω·m)variable range in ±3% Others in ±5% |
6 | Measuring temperature range | 10~50(℃)with precision range in ±1℃ |
7 | Setting of standard temperature | 15~35(℃) with step is 1℃ |
8 | Compensation of auto-temperature | -10~10(℃)with step is 0.1℃ |
![]() |